Modern Hiring Service (MHS), popularly known as Modern, has been extending its rich experience of providing Uninterrupted & Reliable Power, Temperature Control Rental Solutions & Diesel Generator for Rent to a widest range (40kva – 2000kva) of clientele in India and globally. It has state of the art Infrastructure facilities with Depot located at strategic location, modernized ready to install containerized fleet of equipment’s, efficient networking, round the clock service and strong technical capabilities, are the core strengths of Modern.

We are a unique name in the industry to provide our precious clients the best quality Diesel Generator for Rent . The provided service is carried out by our skilled team of professionals in the best possible manner.

Cummins 750 KVA - 900 KVA Generator Specifications

Make: Cummins India
750-900 kVA, 600-648 kWe Prime, 830-900 kVA, 664-720 kWe Standby
 

Engine

  • ƒCummins K38 series, 12 cylinder, Vee, 4 stroke, radiator cooled engine
  • Highly stable and reliable design with square engine
  • ƒƒWell designed air handling system with
    • Dry type, Heavy duty, Replaceable paper element air cleaner with restriction indicator
    • Outboard aftercooling with 2 pump 2 loop system
    • Optimised turbocharger for increased altitude capabilities
  • Best in class fuel economy with
    • PT fuel system with Electronic Step Timing Control (ESTC) injectors which smoothly stabilise engine speed under load with A1 class electronic governing
    • Dual fuel filter system: Pre filter including water separator and Water In Fuel (WIF) sensor and main filter
  • ƒƒStandard integral set-mounted radiator system, designed and tested for 50°C ambient temperatures
  • Full flow spin on lube oil filter
  • Plate type lube oil cooler
  • ƒƒFirst fill of lube oil and coolant
  • ƒƒElectrical starter motor with soft start engagement feature
  • ƒƒBattery charging alternator
  • ƒƒ2 X 12 V DC battery

Alternator

  • Stamford HC alternator frames from Cummins Generator Technologies
  • ƒƒBrushless type, Screen protected, Revolving field, Self excited alternator conforming to IS/IEC 60034-1
  • ƒƒ3 Phase reconnectable winding with 12 terminals brought out for connection
  • ƒƒBetter motor starting capability
  • ƒƒBest in class efficiency
  • ƒƒCompact design with sealed bearings for longer life and lesser maintenance
  • ƒƒImpregnation on all wound components for better mechanical strength

Control Panel

Control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish.
The control panel consists of the following parts:
  • PowerCommand 3.3 Controller
  • ƒƒAluminum bus bars with suitable capacity with incoming/ outgoing terminals
  • ƒIndicating lamps for ‘Load ON’ and ‘Set Running’
  • ƒƒInstrument fuses duly wired and ferruled
  • Air Circuit Breakers (ACB) of suitable rating with overload
    and short circuit protections
PowerCommand 3.3 features

The PowerCommand® control system is an integrated microprocessor-based generator set monitoring, metering and control system with LCD display designed to meet the demands of today’s engine driven generator sets
ƒƒ
  • Intuitive operator interface which includes LED backlit LCD display with tactile feel soft-switches & generator set status LED lamps
  • Integrated digital electronic voltage regulator with configurable torque matching.
  • Digital Electronic Governing with temperature compensation and Smart Starting.
  • SAE J1939 Interface to Full Authority Electronic (FAE) engines.
  • Remote Start-Stop
  • Engine Metering: Oil pressure, High/Low coolant temperature, Low coolant level, Oil temperature, Intake manifold temperature, Battery voltage, Engine speed
  • AC Alternator Metering: L-L Voltage and L-N Voltage, Current (1 and 3 phase), kW, kVAR, Power factor, kVA (three phase and total), and Frequency.
  • Utility/AC bus Metering: L-L Voltage and L-N Voltage, Current (1 and 3 phase), kW, kVAR, Power factor, kVA (three phase and total), and Frequency.
  • Paralleling Control Functions: Digital frequency synchronization and voltage matching, Isochronous kW and kVAr load sharing controls, Droop kW and kVAr control, Sync check, Extended paralleling (Peak Shave/Base Load), Digital power transfer control (AMF), Load govern control, Load demand control
  • ƒƒData Logging: Genset model data, Engine hours, Control hours, Engine starts, Load profile, kWh and upto 32 recent fault codes
  • Engine Protection: Low lube oil pressure, High/Low coolant temperature, Over speed, Battery Over/Under/Weak Volts, Fail to crank/start, Cranking lockout, Low fuel level, Sensor failure.
  • AC Alternator Protection: AmpSentry protective relays for short circuit shutdown, Over/Under voltage, Over/Under frequency, Over current, Overload, Reverse power, Reverse VAr, Phase rotation and Loss of AC sensing.
  • Utility/AC bus protection: Over/Under voltage, Under frequency and Phase rotation
  • Paralleling protections
  • Control Functions: Start-stop with configurable time delay, Real time clock for fault and event time stamping, Exerciser clock and time of day start/ stop, Configurable glow plug control, Configurable cycle cranking, Load shed/ dump as per configurable priority
  • 12 and 24 Volt DC Operation
  • Sleep Mode
  • Programmable I/Os (4 inputs and 4 outputs), expandable with AUX101/102 modules
  • Self-Configuring PCCNet network
  • Modbus Interface (RS485 RTU)
  • InPower Compatible (PC based service tool)
  • Certifications – meets the requirement of relevant UL, NFPA, ISO, IEC, Mil Std., CE and CSA standards

Silencer

Hospital grade Silencer suitably optimised to meet stringent noise emission standards laid down by MoEF / CPCB

Mounting Arrangement

  • engine and alternator are mounted on a common MS fabricated base frame with AVM pads.

Optional

  • Engine: Coolant heater, Oil drain pump, Heat exchanger, No cool, Remote radiator
  • Alternator: PMG
  • Control Panel: Microprocessor / relay based AMF control panel, Battery charger, Auxiliary output relays and remote annunciators
  • Others: Trolley mounted mobile sets

GENERATOR SET SPECIFICATIONS

Model C750D5P
Duty Prime
Power Rating kVA / kWe 750/600
No. of Phases 3
Output Voltage and Frequency (V and Hz) 415 V, 50 Hz
Power Factor 0.8 (lagging)
Current (A) 1043
RPM 1500

ENGINE SPECIFICATIONS

Make Cummins
Model KTA38-G10
MoEF Certified Power (hp) 987
Required Power for Rated kVA (hp) 891
Cooling Liquid cooled (Distilled Water +DCA2)
Aspiration Turbocharged Aftercooled
No. of cylinders 12, Vee
Bore (mm) x Stroke (mm) 159 x 159
Compression ratio 16.7:1
Displacement (litre) 38
Fuel High Speed Diesel
Fuel consumption @75% load with radiator and fan* (litre/hr) 130.4
Fuel consumption @100% load with radiator and fan* (litre/hr) 165
Performance class of generator set ISO 8528-5 G2
Starting system 24 V DC Electrical
Lube oil specification CH4 15W40
Lube oil sump capacity, High-Low level (litre) 140 - 114
Total lubrication system capacity (litre) 155
Lube oil consumption @ full load** (litre/hr) 0.24
Total coolant capacity (litre) 330
No. of banks x Exhaust pipe size (inch) 2 x 8
Total wet weight (Engine+Radiator)## (kg) 5800
Length x Width x Height (Engine) (mm) 2269 x 1436 x 1764
Mean piston speed (m/s) 7.95
Combustion air intake @100% load (±5%) (cfm) 2055
Exhaust Temperature (°C) Alternator Specification 406

ALTERNATOR SPECIFICATIONS

Make Stamford (CGT)
Alternator frame HCI634W
Enclosure IP 23
Voltage regulation (Max.) ±1%
Class of Insulation H Class
Winding Pitch 2-Mar
Stator Winding Double layer lap
Rotor Dynamically balanced
Wave form distortion No load < 1.5 %, Non distorting balanced linear load < 5 %
Maximum Unbalanced Load across phases# less than or equal to 25%
Telephonic Harmonic factor < 2%

GENSET DIMENSIONS

Genset Model Rating
(kVA)
Length
(mm)
Width
(mm)
Height
(mm)
Weight
(kgs.)(Dry)
Std. Fual Tank Capacity
(Ltrs)
C750D5P 750 8000 2600 3000 11900 990